VWR UV-3100PC

The VWR UV-3100PC UV-Vis spectrophotometer is a reliable and easy-to-use spectrophotometer with wide wavelength range, high sensitivity and powerful capabilities. Purchase in Europe includes NanoCuvette™ One.

VWR UV-3100PC UV-Vis spectrophotometer

The VWR UV-3100PC is a reliable and easy-to-use spectrophotometer with wide wavelength range, high sensitivity and powerful function. The VWR UV-3100PC comes with a variety of accessories that will help the user with personalizing the instrument. In addition, the large LCD display (320 x 240 pixels), High Precise A/D and easy to store RAM make the instrument completely unique. The application software offers all the necessary methods, which makes the VWR UV-3100PC ideal for advanced measurements within several fields, including chemistry, biochemistry, pharmaceutics, medicine and education.

 

PHOT_20201228_Spectrophotometers_VWR_UV_3100PC

High sensitivity and wide wavelength range

  • The VWR UV-3100PC has a wavelength accuracy of 0.5 nm, and a wavelength range of 190 nm - 1100 nm, both features increasing the usability of the instrument.

 

PC-controllable application software

  • The VWR UV-3100PC is equipped with an application software that allows for PC control of the instrument. The user can download data to a PC by using a USB interface.

 

Compatible with optional accessories and NanoCuvette™ One

  • The VWR UV-3100PC is compatible with optional accessories such as an automatic eight-cell changer and a peltier thermostatted single cell holder. The VWR-3100PC is also compatible with NanoCuvette™ One (15 mm beam height).

VWR UV-3100PC with high sensitivity and wide wavelength range

The VWR UV-3100PC has excellent spectroscopic skills including high sensitivity. The wavelength accuracy of 0.5 nm makes the VWR UV-3100PC ideal for high accuracy quantitative analysis and detection of low-concentration substances.
The VWR UV-3100PC has a wide wavelength range. The wavelength range of 190 nm – 1100 nm increases the usability of the instrument, due to the fact that it enables the user to measure within both the ultraviolet- and visible region.
 
PHOT_20210702_Spectrophotometers_VWR_PV4_UV_Vis_Accuracy
 
 
VWR UV-3100PC with PC-controllable application software

The supplied application software “UV-Vis Analyst” allows PC control of the spectrophotometer. The internal memory can save 200 sets of data and 200 standard curves which is convenient for check and reload. Data can be downloaded to PC via USB interface. The VWR UV-3100PC includes the following methods: Basic mode, quantitative, wavelength scan, multi-wavelength, DNA/protein and kinetics. The application software offers all the important methods for routine measurements.

 

PHOT_20201228_Spectrophotometers_VWR_UV_3100PC_USB_Port

 

VWR UV-3100PC with a variety of optional accessories

The VWR UV-3100PC is compatible with a variety of optional accessories, including an automatic eight-cell changer that can be used in order to read up to eight cells automatically, and a peltier thermostatted single cell holder that can be used for obtaining precise temperature controlled measurements. The wide range of different accessories available for the VWR UV-3100PC will help to adapt and adjust the units in order to meet specific needs of the user. Some accessories are supplied with the UV-3100PC, including 2 quartz cells, 4 glass cells, 4-position cell holder (10 mm), dust cover and software.

In addition, the VWR UV-3100PC features a beam height of 15 mm and a minimum spectral bandwidth of 2 mm, making the spectrophotometer compatible with NanoCuvette™ One (15 mm beam height).
 
PHOT_20201228_Spectrophotometers_VWR_UV_3100PC_Accessories
 
 
VWR UV-3100PC compared to other instruments

Even though the VWR UV-3100PC maintains some features of older VWR instruments, it is still a major upgrade from previous models. The VWR UV-3100PC is more accurate than older VWR instruments, such as the VWR UV-1200PC UV-Vis, because the wavelength accuracy has been optimized from 2 nm to 0.5 nm.

The VWR UV-3100PC is not only a huge upgrade from previous VWR instruments. It also beats it's competitors on several parameters. The VWR UV-3100PC features a wider wavelength range than the Shimadzu UV-2401PC UV-Vis. Furthermore, the VWR UV-3100PC is more accurate than Biochrom Libra S32PC UV/Vis.
 

VWR UV-3100PC versus Shimadzu UV-2401PC UV-Vis

  • The VWR UV-3100PC has a wider wavelength range than Shimadzu UV-2401PC UV-Vis.

VWR UV-3100PC versus Biochrom Libra S32PC UV/Vis

  • The VWR UV-3100PC is more accurate than Biochrom Libra S32PC UV/Vis.
 
 
VWR UV-3100PC with NanoCuvette™ One, SpectroLink™, and SpectroWorks™ 
 

The NanoCuvette™ One is a cuvette that can be used for measuring both refractive index and absorbance using a spectrophotometer.

The VWR UV-3100PC features a 15 mm beam height and a minimum spectral bandwidth of 2 nm, making the instrument compatible with our NanoCuvette™ One

Today, VWR/Avantor distributes 8 instruments in Europe, which all ship with NanoCuvette™ One.

 

The compatibility of VWR UV-1600PC with cphnano products

 

With our NanoCuvette™ One your VWR UV-3100PC will be able to measure 2 mL / 0.5 µL samples via refractive index for QC and kinetics. You can find a recording here showing how to perform a measurement with NanoCuvette™ One

 

 

In addition to NanoCuvette™ One, you can use SpectroLink™ for simplifying your spectrophotometer workflow to a three step process allowing you to quickly acquire, analyze and extract results. In this way, you don't have to waste more time on trouble with file formats, data transfer or sharing results.

ILLU_20200603_cphnano_Flow_SpectroLink_simple
Together with SpectroWorks™ (the modern approach to spectrophotometry and label-free analysis), SpectroLink™ solves this problem by effortlessly connecting instruments to you browser and analyzing the data.
SpectroWorks™ comes free of charge with every NanoCuvette™ or SpectroLink™ purchase. 
 
 

This information is meant for guidance only. Copenhagen Nanosystems ApS takes no responsibility or liability for the information provided. Please write to sales@cphnano.com if you want to add your UV-Vis instrument to the list or let us know of any mistakes.